Article 4413

Title of the article

APPLICATION OF THE METHOD OF QUASI EXEMPLARY INTERVAL FOR A SEPARATE MEASUREMENT
OF PARAMETERS OF PARAMETER PROBES IN SELF-OSCILLATORY SYSTEMS OF RELAXATION TYPE 

Authors

Golovin Pavel Dmitrievich, engineer, Penza State University, GPD75@yandex.ru
Chernetsov Mikhail Vladimirovich, candidate of technical sciences, associate professor, head of sub-department of  information resources management, Russian State University of innovative technologies and entrepreneurship, oksana_chernecov@mail.ru

Index UDK

 621.317.33

Abstract

A method quasi exemplary time slot is to move the measurement results from the measuring circuit with losses in the measuring circuit without losses. In this exemplary use time intervals equal to the time constant circuit without losses. We propose an unconventional approach that obtaining any information about informative and non-informative parameters of the elements of the equivalent circuit parameter sensors of physical quantities involving energy storage element for instantaneous values of the transition process. Application of the method is justified for two-element equivalent circuit , and three or more elemental schemes , while providing a reduction of measurement time.

Key words

parameter, sensor, transition, process, capacity, method, interval.